VDA 5 or MSA: differences, indices and what fits when
MSA and VDA 5 answer related but different questions. A comparison on the same example shows why the same measurement method can be conditional by one and suitable by the other.
- Neither is better; usually the customer decides.
- MSA: %GRR and ndc from repeatability and reproducibility.
- VDA 5: Q_MS and Q_MP from all influences, with U for conformance decisions.
- In the example: %GRR 11.1 % (conditional), Q_MP 9.6 % (suitable).
Contents
The starting point
A supplier has two customers. One writes “measurement system analysis per AIAG MSA” in its quality requirements, the other “measurement process capability per VDA 5”. For both, the same diameter is measured with the same micrometer. After the evaluation, the report for the first customer says “conditionally acceptable”, the one for the second “suitable”. Did someone make a mistake?
No. The two rule sets answer similar but not identical questions, use different formulas and have different limits. This article shows the differences using exactly this example, step by step.
The short answer
Neither is “better”. Both check whether a measurement method is fit for a task, but they ask the question differently. The AIAG MSA asks: how much of the tolerance or variation does the measurement system use up through repeatability and reproducibility? VDA 5 asks: how large is the total measurement uncertainty when all influences count, including calibration, temperature and form deviation? In practice the customer almost always decides which one applies.
Side by side
| AIAG MSA | VDA 5 | |
|---|---|---|
| Origin | AIAG (Ford, GM, Chrysler), since 1990, 4th edition 2010 | VDA, since 2003, 3rd edition 2021; based on ISO 22514-7 |
| Spread | North American supply chain, known worldwide | German OEMs and their suppliers |
| “Measurement system” means | instrument, appraisers and method together | only the instrument with its standard; the whole is called measurement process |
| Indices | %GRR, ndc, bias and linearity separately | QMS and QMP from an uncertainty budget |
| Influences | repeatability, reproducibility, part variation | also calibration, resolution, bias, temperature, object, stability and more |
| Limits (per source) | %GRR up to 10 % acceptable, up to 30 % conditional | QMS up to 15 %, QMP up to 30 % (recommendation) |
| Extra benefit | shows whether the system distinguishes parts (ndc) | provides U for conformance decisions per ISO 14253-1 |
Bosch Booklet 10 sits in between: the type 1 study with Cg and Cgk checks the instrument on a standard, similar to the measurement system stage of VDA 5, while procedure 2 follows AIAG MSA.
Same example, two verdicts
For the diameter 10 ± 0.05 mm from MSA 2 and VDA 5, MSA gives %GRR = 11.1 %, i.e. conditionally acceptable. VDA 5 arrives at QMP = 9.6 % for the same measurement process, i.e. suitable, even though more influences count there.
The reason lies in the formulas. %GRR relates the 6 σ spread to the tolerance, QMP twice the expanded uncertainty, 2 · U = 4 · u. With only repeatability and reproducibility, QMP would be two thirds of %GRR, here 7.4 %. The further contributions raise it to 9.6 %, and the VDA 5 limit is 30 % instead of 10 %.
Recalculated with the numbers of the two articles, all values in µm, tolerance T = 100 µm:
| Quantity | Calculation | Result |
|---|---|---|
| √(EV² + AV²) | √(1.19² + 1.41²) | 1.843 µm |
| %GRR (MSA) | 6 · 1.843 / 100 | 11.1 % |
| Q with EV and AV only | 4 · 1.843 / 100 | 7.4 % |
| other contributions uother | calibration, bias, form, temperature | 1.550 µm |
| uMP | √(1.843² + 1.550²) | 2.408 µm |
| QMP (VDA 5) | 4 · 2.408 / 100 | 9.6 % |
Three things stand out. First: the factor is different, 6 for MSA, 4 for VDA 5. Second: VDA 5 includes more influences, which makes Q larger. Third: the limits differ, 10 % versus 30 %. In the end %GRR at 11.1 % is just above its limit, QMP at 9.6 % far below its own.
What both have in common
- Both need the same basic experiments: measurements on a standard and a study with production parts and appraisers.
- Both relate the result to the tolerance and thus say whether the measurement method is fit for this characteristic.
- Both require sufficient resolution before any calculation.
- For both: a poor number is a reason to look for the cause, not just a verdict.
What fits when
- Customer requires AIAG or Bosch Booklet 10: %GRR and ndc, at Bosch also Cg and Cgk.
- Customer requires VDA 5: uncertainty budget with QMS and QMP.
- Conformance decisions, test lab, first articles near the limit: measurement uncertainty per VDA 5 or GUM, because only it provides U.
- Process control and telling parts apart: %GRR related to process variation and ndc say more.
- Both kinds of customer: the experiments overlap; the same gage R&R feeds both assessments.
The criticism of both is well known: when %GRR is too high, MSA does not show where the variation comes from; the VDA 5 budget is only as good as the contributions and distribution assumptions entered.
Both in STATlum
In STATlum an “MSA 2” study and a “VDA 5” study sit side by side on the same characteristic. The measurement series of the gage R&R can be used in the VDA 5 study as the “procedure 2” experiment.
Download the free versionFree MSA software: what STATlum Free does
Frequently asked questions
Is VDA 5 stricter than MSA?
Not in general. VDA 5 counts more influences, but sets the limit at 30 % and calculates with four times u instead of six times σ. In the example VDA 5 is milder; with a large temperature or object influence it can be the other way round.
Do I need a gage R&R for VDA 5?
Usually yes, when appraisers have an influence: it provides the repeatability on the part and the appraiser influence for the budget.
Can I convert an MSA result into Q_MP?
Only partly. Without the other influences part of the budget is missing; %GRR alone gives only a lower bound for Q_MP.
Sources
- Dietrich: Wo liegen die Unterschiede? Vergleich von MSA und VDA Band 5 (German), QZ 6/2011
- Minitab: VDA, AIAG, MSA Oh My!
- Muelaner: VDA-5, Combining Uncertainty Evaluation with Gage Studies
- AIAG: Measurement Systems Analysis, Reference Manual, 4th edition
- VDA: Volume 5, Measurement and inspection processes, 3rd edition 2021
This article explains the method. It does not replace the guideline that applies to your part or the professional assessment of an actual study.