Gage R&R calculator

Paste the measurements of a gage R&R from Excel: the calculator determines EV, AV, GRR, PV, %GRR and ndc with the ANOVA method, calculated as in STATlum. The calculation runs only in your browser, nothing is sent or stored.

or limits

Settings

Common: %GRR up to 10 % acceptable, up to 30 % conditionally acceptable, ndc of at least 5. What counts is the requirement for your part.

How the calculator works

ANOVA method for the crossed design as in STATlum: if the part × appraiser interaction is not significant (p > 0.25), it is pooled into repeatability (MSW′), otherwise shown separately. Spread 6 · GRR, ndc rounded down.

EV=MSW′
AV=MSP−MSW′n·r
PV=MST−MSW′a·r
GRR=EV2+AV2
TV=GRR2+PV2
%GRR=6·GRRT
ndc=1.41·PVGRR

Explained step by step, with the same example data: Gage R&R with %GRR and ndc. With the example data the calculator gives the same values as the article.

Prefer an Excel file: free MSA Excel templates, without macros and with open formulas.

The complete study

ANOVA table, confidence intervals, average and range method, charts and report are produced by STATlum Free, free of charge and offline on Windows. Free MSA software